Difference between revisions of "System attributes"
(10 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
To distinguish with user-declared attributes, the key (name) of a system attribute has a space as the first character. | To distinguish with user-declared attributes, the key (name) of a system attribute has a space as the first character. | ||
− | Below is the list of system attributes in the Netlist database. Note that depending on the flow, a DesignObj may or may not have a particular attribute. | + | System attributes are not written out in the Verilog netlist output, unless when the runtime flag "db_verilog_writer_write_internal_data" is enabled. |
+ | |||
+ | Below is the list of system attributes in the Netlist database. Note that depending on the flow, a DesignObj may or may not have a particular attribute. Some attributes depend on runtime flag settings. | ||
<nowiki> | <nowiki> | ||
Instance | Instance | ||
Line 13: | Line 15: | ||
(" is_concurrent", "1") // ReadPort/WritePort only | (" is_concurrent", "1") // ReadPort/WritePort only | ||
(" BLOCKING", "1") // ReadPort/WritePort only | (" BLOCKING", "1") // ReadPort/WritePort only | ||
+ | (" from_array_inst", (full_name)?full_name:inst_name) | ||
+ | (" instantiated_primitive", "1") // for directly-instantiated Verilog primitives | ||
Net | Net | ||
(" basic_constant", const_val) // is driven by a constant and also connected to a blackbox | (" basic_constant", const_val) // is driven by a constant and also connected to a blackbox | ||
(" wired", "1") | (" wired", "1") | ||
(" is_up_dir", "1") | (" is_up_dir", "1") | ||
− | (" original_name", name) // | + | (" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled |
+ | (" original_name", name) // original name in the input file, for nets being renamed to avoid to name conflict | ||
(" supply0", "1") // from Verilog "supply0" construct | (" supply0", "1") // from Verilog "supply0" construct | ||
(" supply1", "1") // from Verilog "supply1" construct | (" supply1", "1") // from Verilog "supply1" construct | ||
Line 29: | Line 34: | ||
Port | Port | ||
(" orig_port_name", name) | (" orig_port_name", name) | ||
− | (" created_from_test_cell", "1") // created from test | + | (" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled |
+ | (" created_from_test_cell", "1") // created from test cell in SynLib | ||
(" open_port", "1") | (" open_port", "1") | ||
PortBus | PortBus | ||
(" orig_port_name", name) | (" orig_port_name", name) | ||
Netlist | Netlist | ||
− | (" language", | + | (" language", language_name) // the language it comes from - "edif", "verilog", "vhdl", "upf", "synlib", "upf" |
(" cell_name", module_name) // original module/unit name in input file | (" cell_name", module_name) // original module/unit name in input file | ||
(" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL) | (" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL) | ||
− | (" primitive", "1") | + | (" primitive", "1") // netlist is a Verific primitive |
(" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance | (" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance | ||
(" changed_by_interface_overwrite", "1") | (" changed_by_interface_overwrite", "1") | ||
(" changed_by_hier_ref", "1") | (" changed_by_hier_ref", "1") | ||
− | (" celldefine","1") | + | (" celldefine","1") // netlist has "`celldefine" directive |
− | (" package", "1") | + | (" package", "1") // netlist comes from a VHDL package |
− | (" upf_uniquified", "1")) | + | (" upf_uniquified", "1")) // from ups reader |
+ | (" is_sequential", 0) // from synlib reader | ||
+ | (" is_latch", 0) // from synlib reader | ||
</nowiki> | </nowiki> | ||
Line 62: | Line 70: | ||
</nowiki> | </nowiki> | ||
− | + | You can get a particular attribute. For example: | |
+ | |||
<nowiki> | <nowiki> | ||
− | + | if (netlist->GetAttValue(" language")) { | |
− | + | Message::Msg(VERIFIC_INFO, 0, 0, " from %s", netlist->GetAttValue(" language")); | |
− | + | } else { | |
− | + | Message::Msg(VERIFIC_INFO, 0, 0, " no language"); | |
− | + | } | |
− | + | ||
− | + | ||
</nowiki> | </nowiki> |
Latest revision as of 23:12, 10 September 2022
Verific system attributes are attributes added and attached to DesignObjs (Design Objects) during the process of building the Netlist Database.
To distinguish with user-declared attributes, the key (name) of a system attribute has a space as the first character.
System attributes are not written out in the Verilog netlist output, unless when the runtime flag "db_verilog_writer_write_internal_data" is enabled.
Below is the list of system attributes in the Netlist database. Note that depending on the flow, a DesignObj may or may not have a particular attribute. Some attributes depend on runtime flag settings.
Instance (" named_group", named_group) (" GATE_TYPE", "gated_clock") (" creating_port_refs", "1") (" enum_encoding", user_encoding) // DFF (" PROCESS_ID", buffer) // ReadPort/WritePort only (" is_concurrent", "1") // ReadPort/WritePort only (" BLOCKING", "1") // ReadPort/WritePort only (" from_array_inst", (full_name)?full_name:inst_name) (" instantiated_primitive", "1") // for directly-instantiated Verilog primitives Net (" basic_constant", const_val) // is driven by a constant and also connected to a blackbox (" wired", "1") (" is_up_dir", "1") (" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled (" original_name", name) // original name in the input file, for nets being renamed to avoid to name conflict (" supply0", "1") // from Verilog "supply0" construct (" supply1", "1") // from Verilog "supply1" construct (" specify_cond", cond_pp) // SDF only (" package_net", "1") (" global_clocking_ref", "1") // SVA (" sva_clock_ref", "1") // SVA (" enum_encoding", user_encoding) NetBus (" original_name", name) Port (" orig_port_name", name) (" init_val", value) // initial value, if compile flag DB_PRESERVE_INITIAL_VALUE is enabled (" created_from_test_cell", "1") // created from test cell in SynLib (" open_port", "1") PortBus (" orig_port_name", name) Netlist (" language", language_name) // the language it comes from - "edif", "verilog", "vhdl", "upf", "synlib", "upf" (" cell_name", module_name) // original module/unit name in input file (" from_netlist_reader", "1") // from structural netlist reader (not synthesized from RTL) (" primitive", "1") // netlist is a Verific primitive (" unknown_design", "2")) // "1" for Verilog instance, "2" for VHDL instance (" changed_by_interface_overwrite", "1") (" changed_by_hier_ref", "1") (" celldefine","1") // netlist has "`celldefine" directive (" package", "1") // netlist comes from a VHDL package (" upf_uniquified", "1")) // from ups reader (" is_sequential", 0) // from synlib reader (" is_latch", 0) // from synlib reader
To access the attributes of a DesignObj, use macro FOREACH_ATTRIBUTE. For example:
C++:
Netlist *netlist = ....; // or any other derived class from DesignObj Att *attr; MapIter mi; FOREACH_ATTRIBUTE(netlist, mi, attr) { const char *key = (attr) ? attr->Key() : 0 ; if (!key) continue ; if (key[0] == ' ') continue ; // if you want to skip system attributes // Do whatever you want here, e.g. Message::Msg(VERIFIC_INFO, 0, 0, " -- attribute name: %s, value: %s", attr->Key(), attr->Value()); }
You can get a particular attribute. For example:
if (netlist->GetAttValue(" language")) { Message::Msg(VERIFIC_INFO, 0, 0, " from %s", netlist->GetAttValue(" language")); } else { Message::Msg(VERIFIC_INFO, 0, 0, " no language"); }