Difference between revisions of "Constant expression replacement"
From Verific Design Automation FAQ
(One intermediate revision by the same user not shown) | |||
Line 6: | Line 6: | ||
I expect the range of "foo" to be [7:0]. How do I get the range [7:0]? | I expect the range of "foo" to be [7:0]. How do I get the range [7:0]? | ||
+ | If run-time flag "veri_replace_const_exprs" is set, during static elaboration, Verific will replace the following constant expressions with their respective values: | ||
+ | # Bounds of packed and unpacked ranges in all data declarations. | ||
+ | # Default values of all declared objects if those are constant. | ||
+ | # Delay values. | ||
+ | # Reject and error limits of VeriPathPulse values. | ||
+ | # Indexed expressions only if the indexed expression is a bit-select on the LHS of a continuous assignment or output/inout port of module or gate instantiation. | ||
− | + | Above specific replacements are not done on un-elaborated modules because the parameter values they depend on might be changed later by other applications. | |
In C++: | In C++: | ||
− | RuntimeFlags::SetVar(" veri_replace_const_exprs", 1) ; | + | RuntimeFlags::SetVar("veri_replace_const_exprs", 1) ; |
In Tcl: | In Tcl: | ||
set_runtime_flag "veri_replace_const_exprs" 1 | set_runtime_flag "veri_replace_const_exprs" 1 |
Latest revision as of 08:51, 17 November 2023
Q: Does Verific replace constant expressions with their respective values?
I have in my Verilog code:
parameter size = 8; reg [size-1:0] foo;
I expect the range of "foo" to be [7:0]. How do I get the range [7:0]?
If run-time flag "veri_replace_const_exprs" is set, during static elaboration, Verific will replace the following constant expressions with their respective values:
- Bounds of packed and unpacked ranges in all data declarations.
- Default values of all declared objects if those are constant.
- Delay values.
- Reject and error limits of VeriPathPulse values.
- Indexed expressions only if the indexed expression is a bit-select on the LHS of a continuous assignment or output/inout port of module or gate instantiation.
Above specific replacements are not done on un-elaborated modules because the parameter values they depend on might be changed later by other applications.
In C++:
RuntimeFlags::SetVar("veri_replace_const_exprs", 1) ;
In Tcl:
set_runtime_flag "veri_replace_const_exprs" 1