Notes on analysis

From Verific Design Automation FAQ
Revision as of 20:53, 31 October 2023 by Hoa (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

First, please read this article: Defined macros become undefined - MFCU vs SFCU.

Q: Can I use 'veri_file::Analyze()' to read SystemVerilog input files one by one, all of them belonging to one compilation unit?

Yes. But if you have multiple files, it’s better to use 'veri_file::AnalyzeMultipleFiles()'.

'veri_file::AnalyzeMultipleFiles()', besides analyzing each file, also:

  • opens and ends the compilation unit
  • processes –v and –y options
  • removes include directories
  • processes root module
  • undefines user-defined macros, including command-line macros
  • resets compile directives (e.g. `default_nettype, `timescale)

If you use 'veri_file::Analyze()' to analyze each file one by one, after all the calls to 'veri_file::Analyze(), depending on the application, you may want to run veri_file::RemoveAllIncludeDirs() and veri_file::EndCompilationUnit().

If the application calls any elaboration API (e.g. veri_file::Elaborate()), there is no need to call veri_file::RemoveAllIncludeDirs() and veri_file::EndCompilationUnit() because the elaboration API will call those APIs before actual elaboration.